Hello and thank you for joining us today for our webinar on the Essential Principles of Power, Part one: Voltage, Current, and Power from AC Line to PWM with Ken Johnson. My name is Hilary Lustig, and I'm the Marketing Communications Manager here at Teledyne LeCroy. We're glad that you could join us today. A few housekeeping items before we begin today's presentation. This webinar is being recorded and will be available on demand by tomorrow morning. You will each receive an email when it's available, along with a link to download today's slide deck. In addition, we've put some resources on the handout section of the control panel. You'll find a copy of the slides there as well, if you'd like to follow along. To keep us running on time, we will hold questions and answers at the end of today's presentation. However, you are welcome to submit the questions at any time using the Questions section of your control panel that, again, is on the right side of your screen. Thanks again for joining us. I'm now going to turn the presentation over to Ken. Hi, Hilary. Thank you very much, and welcome to our webinar. Just very quick opening comments, a little bit about who Teledyne LeCroy is. We've been around for a long time, more than 50 years, and we're located right here in New York in the United States. That's our corporate headquarters where much of our manufacturing is done as well. We have a lot of firsts. We were the first people to make a digital storage scope. We have the world's only 12-bit, 1 GHz, 8-channel scope, and we have the world's only 12-bit, 8 GHz oscilloscope. And we were first to 100 GHz as well, real time. So pretty cool stuff. We also have a variety of companies involved in the field of protocol analysis, on the software development side. In 2012, we were acquired by Teledyne Technologies and renamed Teledyne LeCroy. A little bit about myself ? graduate EE from Rensselaer Polytechnic Institute, and I play ice hockey. I've been with LeCroy for a long time, well over 15 years. Prior to that, I had some real-world experience in the high-voltage test and measurement field, so it's a nice match here between oscilloscopes and what we would consider very high voltages. Very quickly, this is our agenda for the day. I won't reread it, but you'll see what it's all about. We'll cover all these different topics. Quickly, a focus on power. This particular seminar, I always joke with people power means lots and lots of different things. It's important that we're specific. In the next slide, I'll talk about which area we're going to focus on today. You could define power in any of these different ways. They all mean very different things. The one we're going to focus on today is really the top one: utility grid, household, line, mains, whatever power. We'll touch on the output of the drive as well or the output of the inverter subsections when power conversion is being utilized. But, primarily, we're going to talk a lot about this. It's the 50, 60 Hz AC signals that are the input to most power conversion systems and also the outputs. The PWM signal outputs are also created through the power conversion process itself. Very quickly, a quick power overview. We all know, we tend to take it for granted, especially on the utility side until it's not there. Power is generated, used to be primarily by stationary localized generating plants, a big rotating generator machine, that would supply bulk, high voltage and current to a transmission line. More recently, we're seeing this trend towards distributed generation where generation is almost everywhere, and it could be solar PV panels on someone's roof or it could be distributed wind or something like that. In any case, if it has to go someplace a long distance, it's going to be transmitted and distributed. That's what's meant by T&D, the transmission and distribution to your home or your commercial business or whatnot. At the end, it's consumed, could be consumed directly from utility AC with no power conversion, or it could be converted through some sort of drive or switch-mode power supply or inverter or converter of some kind. There's different names whether it's AC or DC to AC or DC. You might, if you know anything about the transmission and distribution grid, and the generation itself too is remarkably inefficient. It averages only about 30-something percent efficient. It's pretty bad. That's taking into account the BTUs of the fuel burned, for fossil fuels and all the losses that occur all the way down the line through cables, transformers, everything, getting to your house. So quite a bit of losses. It's quite terrifying actually how much power is lost in the transmission generation, transmission, and distribution. In any case, let's get right to it. We're going to just cover the basics here of AC line voltage, current, and power. This topic seems very simple. There's a lot of complexity to it, especially when you get into the power measurements of the signals and or three-phase capabilities as well. First, let's focus on the line voltage, AC sinusoidal line voltage. You might hear this called lots of different things. It could be called line power or household or grid power or power line utility mains. These all mean the same thing. It's what comes off the utility wires to your home or business or if you're grid-disconnected, it could come right out of the output of your inverter. It's specified as volts. It's always really volts RMS, but to make things even more confusing, it's typically stated as volts AC. All these terms are used interchangeably in this context. They all essentially mean the same thing, which we'll cover. You could have a single-phase system, you could have a three-phase system, there's a variety of different single-phase systems you can have, two-wire or three-wire. A good example of a three-wire single-phase system would be a 240 V input to your home. There are two lines and a neutral. Single-phase would be half of that, the 120 V to neutral. Three-phase can be three-wire or four-wire. We'll describe why that is. You could have more than three phases. It's not common, especially from a utility. It's getting a little more common where redundancy is required. A great example would be a six-phase motor, perhaps on a vehicle, where if something happened to one set of three phases, the other set of three phases would still have enough power to at least limp you to a home or someplace where you can get serviced. For voltage, the measurement reference point could be to a neutral in a single-phase or a two-phase case. It could be to another line or in a three-phase case. It could be to another line or phase when you have two or three phases. Something that's important to know is ground is a safety connection from a chassis to earth, and it's a protection against faults. It's not neutral. These things ideally are the same thing. They don't have to be in a technical sense. That's just a subtlety. It's important to understand, especially if you're working around these kinds of voltages. The shape, it's nominally a sine wave. It's not a pure sine wave. There's always some distortion in real-world systems. We have some real examples we can show you what that looks like. But, typically, the distortion is contained to within less than 5%. Okay. Covering the basics. What is this that we're dealing with? Well, the first thing to understand is that the AC voltage we're getting from the utility is a vector, and it's a rotating vector that has a magnitude and an angle at any given point in time. The magnitude is essentially constant, theoretically at least, in practice mostly, but the angle is obviously changing all the time. The angle that it's changing is related to the frequency of the voltage that's supplied to us. Typically, the single phase is referred to as a line voltage. Obviously, you have one phase, so the measurement's from line to neutral, and that's usually just referred to as line. As we mentioned, it rotates. The speed of rotation of that vector is defined by the frequency of the power signal that's supplied to us. In any given moment in time, the voltage magnitude is simply volts times sine of the angle of rotation in radians. As it rotates, it's changing magnitude even though the vector magnitude itself doesn't change. The signal magnitude will change as we see it. So what does that mean? It means it looks like a sine wave. At some point, the angle is going to result in a value of zero. The sine of the angle is going to result in a value of zero. Even though you have a constant magnitude vector, you get a situation where the voltage output is zero. That's where it crosses the middle point of the sine wave. The frequencies we talked about in Europe, 50 Hz mostly, in the US, 60 Hz, Asia is a mix of both. There are other special cases where there are usually non-utility supplied power. Naval runs a lot of 400 Hz, some mining applications are 25 Hz. The reasons for why they chose those years ago are probably beyond our discussion today. Okay. So what does the magnitude look like, and what are we dealing with when somebody says, hey, I've got a 120 V signal? What does that mean? Remember, the voltage is stated as a 120 V or V AC, but that's V RMS. And that's a rated voltage for line to neutral. If you want to know the peak voltage, you have to take that RMS voltage and multiply it by the square root of two. For a 120 V AC supply, which is what we have in our homes here in the US, what that means is you have about a 170 V peak positive and a peak negative of -170 V. Therefore, your peak-to-peak is two times the peak or 340 V, and that plus peak and the minus peak is part of a continuous waveform. If you wanted to measure that peak-to-peak, you need a probe that can at least measure a full 340 V signal swing. If the voltage is rectified and filtered, then you're going to get a DC value that's equivalent to the peak voltage or 170 V DC. You might have heard the term true RMS and wondered what that meant. I'll be charitable. It's not an engineering definition. It's really a marketing definition. It is a way for companies that are doing the right thing to describe what they're doing is accurate when companies that are doing the shortcut not quite right thing are marketing their instruments as having RMS capability. What that means is that very inexpensive field test equipment could take a measurement shortcut. That measurement shortcut is they'll just measure the peak-to-peak voltage, and they'll divide it by the square root of two. Then they'll say, well, that's RMS, but that's not an RMS reading. It's what I would call a false RMS. It relies on a bunch of assumptions about the signal being true. It's only good for a pure sine wave. I'd hate to assume that. You should not assume that. Therefore, companies that do a true RMS calculation and not an assumption from the peak-to-peak value are marketing their products as true RMS. Realistically speaking, any sampling technology product, a product, whether it's a really good quality multimeter, a scope, a power analyzer, etc., something that uses ADCs, digital sampling technology, will be calculating in what we call true RMS mode all the time. We won't call it that. We don't call our calculation true RMS. It's just RMS voltage or RMS current, the same for power analyzers, and you can assume it's done correctly. Okay, if you have a three-phase system, what does that mean? It means you have three voltage vectors, they're separated in angle by 120 degrees. By definition, the system is balanced in that case, so the angle should be separated by the same amount and the vector should be of equal magnitude. What that means is if you sum all three voltages up, then you get 0 V at the neutral. That's a pretty good assumption; that's the way it should work. Typically, the three phases, especially on a sinusoidal input or grid supplied power, are referred to as A, B, and C phase, but many other conventions could be used, like 1, 2, 3, L1 for line 1, L2, L3, or R, S, and T. It can get a little confusing, but they just mean different vectors in this three-phase system. The three-phase vector system rotates just as the single-phase case does. It's rotating because the generator that creates it is rotating, and the generator that creates it is rotating at a certain frequency, and given the number of poles on the stator and the rotor in the generator, you get the frequency that's output by the utility, 60 Hz or 50 Hz. When you receive it at your home, you're going to see that, just like in the single-phase case. They all stay locked together, by nature of the design of the transmission equipment, to that given frequency. They're rotating just as in the single-phase case. When they do, now instead of having one sine wave, you have three, and they are separated by 120 degrees in phase or an equivalent amount in time, depending on the frequency. At any given point in time, one of those voltage vectors has a magnitude of volts times sine of alpha, with the alpha being the angle of rotation for that vector. I always get this question whenever I talk about it. People ask me why three phases? Why not four? Why not five? Or why not two? Three was probably just a pretty good trade-off back in the day. It provides a more efficient way to generate power. It provides for a nicely balanced system because you've got a lot of mass rotating on a generator. It's easier to manufacture, it's lower cost to manufacture three-phase for a given power compared to two-phase or one-phase. You also get better control capability with three-phase systems. You might ask why not four or five? The answer is probably, well, they had to do something, and three was enough. Nobody saw a compelling need to go to four, so here we are, 100-plus years later with three-phase systems being pervasive and ubiquitous. Okay. Let's talk about measuring voltages in a three-phase system. You can measure the voltage in two ways. You can measure line-to-line, like I show here with V A-B, and that's also referred to as phase-to-phase, or you can measure line-to-neutral, and that would be referred to what typically is like V A to neutral or V A-N. That is two different ways to measure the voltage. If you wanted to convert one to another, at least in a magnitude sense, then you would multiply the line-to-neutral by the square root of three, or the line-to-line divided by the square root of three to get the line-to-neutral. That doesn't take into account the phase shift, there is a 30-degree phase shift, as you can infer. If you remember all the geometry, which I will not rederive here, the angle between those two is 30 degrees. You could rederive the A to B phase angle compared to A to N, if you wish to. Okay. We're going to get into a little bit more about why you have these two different ways to measure voltage and which one is used when. One of the reasons is, you could have different winding configurations. For instance, you could have a wye or a delta. The wye looks like the letter Y, and the delta looks like the Greek letter delta, and it's sometimes represented that way. In the wye connection, the neutral is present in the winding, but sometimes it's not accessible. You might not be able to get to it physically and put a probe on it, let's say. But it is a very common configuration, especially with large motors. The delta is less common, especially on the motor side, but more common in small motors. This one has a neutral that's not present in the winding, so you can see the windings just all connect to each other, and there's no neutral that's there. There are a lot of other corner case, different three-phase connections as well, but these are the two the vast majority of them are either wyes or deltas. Obviously, if you have a delta winding, there's no neutral, so you can't probe line-to-neutral. Therefore, the convention whenever you're talking about a three-phase system is always to talk about the voltages of line-to-line, because no matter what kind of system you have, you can always measure a voltage line-to-line, whereas you cannot always measure a line-to-neutral. Okay, so again, just like the single-phase case, it's referred to as V AC but it's V RMS. As I just stated, that rated voltage is always the line-to-line rated voltage. That's a little different than the single-phase case. The single-phase case, it's rated line-to-neutral. If you look at what those three vectors look like, and I plotted them here now with the scale, if we measure V peak-to-peak or V peak, we can see that our voltage is going to be +679 V when it's rated 480 V line-to-line. That's not a direct times the square root of two. It's derived from a value from the line-to-neutral equivalent voltage. The peak-to-peak is roughly 1,400 V or a little less than 1,400 V. If you've ever wondered why high-voltage differential probes usually have a voltage range of 1,400 or 1,500 V, that's why, because they were originally conceived of as needing to have enough range to be able to support a 480 V system, having roughly 1,400 V peak-to-peak. It doesn't help so much if you're in Canada and you use 600 V, and it doesn't help so much if your voltage goes a little high, but that is why a lot of those diff probes historically have 1,400 V or 1,500 V signal swing. If we look at what happens if you were to rectify that three-phase system, you really have to convert the voltage into a line and neutral basis, which is done here. Now you can see the peak-to-peak is +400 to -400 V for a 480 V AC three-phase system case. The math says 392, and so twice that, roughly 800. If I took all three of those phases and rectified them all with something we call the six-pulse rectifier, meaning it's rectifying every one of those sine waves, then we're going to get a voltage value that's about 679 V DC. If you ever wondered how we get that kind of voltage value, that's how we do it. It's a line-to-neutral rectified signal, and all three phases are added together. When they add together, you get something in a range of 700 V DC. This is just a comparison of the same signal. It's a 480 V AC, but on the right, that's the line-to-line values, and on the left is the line-to-neutral values. If you take a careful look here, you can see I've even represented it to be a slight phase shift. Just to recognize, it's not only a magnitude difference, it's also a phase difference as well between the two. Okay. You might have heard of the term utility voltage classes. I'm showing my age here by referencing ANSI C84. But that's a standards organization. IEEE has mostly taken over their functions. The IEC has similar Type-Classes. The voltage classes kind of break down. As I show here, there's what we consider, usually call low-voltage safety class. It could be 50 V or 60 V. It's very commonly used. It's what somebody can reasonably be expected to be able to touch with the human body and not be harmed. It's not a utility voltage class, though, per se. The utility voltage classes really start with the 600 V class, which you might find ironic. That's called low voltage. It's also called distribution level voltage. If you took a full 600 V AC, which is line-to-line rated, and you did the math and calculated what the DC bus would be of that three-phase system rectified, you'd find out it's just shy of a 1,000 V DC. This is also commonly thought of as a 1,000 V RMS class. If you've ever also wondered why do most high-voltage differential probes have a 1,000 V safety rating, now you know why. It's because when you look at the 600 V class and you do the math, the typical DC value of that three-phase system rectified, which is present in the drive, is just under a 1,000 V RMS. Now you get at lower voltages like 110 V, 120 V, 208 V, 220 V, 240 V, etc. Those would be in what I call a 500 V RMS subclass, which is why sometimes you see a low-cost inexpensive probe be rated for 500 V RMS. Typically, it's one of the three-phase. It's the 400 V, 480 V, or 600 V class. Sometimes they rate them a little less simply to account for the voltage drop that you get from the incoming to a building, through a long running cable to an actual load. So 380 V and 400 V essentially mean the same thing. It's just a question of perspective for the user. Is it at the end of the internal run of cable from the 400 V supply, or is it right at the 400 V supply, etc.? The max voltage is the 600 V plus 15%. If you do the math on that, that's 690 V. If you rectify that, that's where you get to just under a 1,000 V RMS for a DC rectified. There are also a class of voltages called medium voltage, which those who work with printed circuit boards might be surprised to hear. It goes all the way up to 69,000 V. That's, generally speaking, is thought of as a generation distribution sub-transmission class. If you look at that, maybe you live outside, in a neighborhood where there's a pole top transformer hanging off the utility pole, that's usually like a in the United States, a 14.4 kV or thereabouts transformer that steps down to 120 V, 240 V, which goes in your home. Like, see a big pad mount transformer outside your commercial building. That might be 35 kV or 69 kV, step down to 480 V or 600 V depending on where you are, which then goes in your building and gets stepped down further as necessary. If you're generating, that's typically 25 kV. Various devices used to measure high voltage include a lot of specialized probes used just with scopes, but also a variety of other test equipment. It could be a high-voltage diff probe with a 1, 2, or 6 kV common mode or VRMS safety rating isolated product. Some of those are very good. We make one that's really very good. It costs more than the cheap ones you can find online for a few hundred bucks. With that, you get better accuracy and better CMRR performance, none of which you probably need if you're just measuring 50 or 60 Hz voltages, but if you're measuring drive outputs as well, you are going to want good CMRR performance and good, flat gain accuracy. You might also use a high-voltage passive probe that's shown in the top right corner here. That's a single-ended probe, not differential. If you're going to measure line-to-line, you have to have a differential probe. If you're measuring line-to-neutral or something else, then the passive probe works fine. They generally reward you with a little more bandwidth than the differential probes do. There are differential amplifiers from LeCroy and other companies as well, that take a BNC input and output some lower signal value that's from a differential input to a single-ended output that could be used to drive the scope. If you're on the utility side, you might have heard of something called potential transformers or PTs, and they're not DC rated. They're rated to operate around 50 to 60 Hz, plus or minus maybe 10 Hz or so. They have limited, obviously, limited high-frequency response. But good for measuring the run-of-the-mill 50, 60 Hz signals. Right. So this will be a pause really quickly, to ask you to help us understand what do you use to measure voltage, and this is always very interesting. Tell us a little bit about what you do. We'll present the results in just a moment while you vote, and we'll give you about 30 seconds for this. We still see some more answers coming in, so we're going to give it just a few more seconds, and we will show the results momentarily. Okay. I'm going to try to look at the results here. It looks like a very good number of people use ? more than anyone else ? use these single-ended probes. Second is the differential probes. That's probably the bulk of what the needs are. Not too many people use PTs. Not surprising. A few people use a differential amplifier, and some other people use some other types of technologies as well. Okay. Very interesting. Thanks for participating in that. Alright. Let's talk about current. It's going to look a lot the same. This is pretty much a cut-and-paste from the previous slide about voltage. RMS is the units of currents, but it's referred to a bunch of different ways. The big difference here is the measurement reference point. It's always a line current. You don't have a line-to-line current, so to speak. There's always a line current in the wye system, that means that all current flows are to neutral, so the line currents and the winding currents are the same thing. In a delta system, line currents flow into a terminal, one of the three apexes of the triangle or delta, and then those currents from the apex flow to two different windings. It's different. In a delta system, if you want to know what the current is through the winding itself, it's pretty hard to find because it's coming from two different directions. Again, nominally, it's a sine wave. It's not always a pure sine wave. Utilities are allowed to have up to 5% distortion on their line. It doesn't sound like a lot, but it can make a waveform look quite a bit different, as we'll show in a few minutes. Okay. Like the voltage, the single-phase vector rotates. At any given time, the instantaneous magnitude of that rotating vector is a product of the vector magnitude and the angle of rotation. Again, it looks like a sine wave, just like the voltage case. For a three-phase case, you have three. They're 120 degrees separated from each other. They rotate as before with the three-phase case, and it looks a lot like the three-phase voltage case. The three sinusoidal waveforms are separated by 120 degrees. Ideally, they have an equal peak amplitude if the load they're driving is balanced. If not, you might find some minor variations in the amplitude. Otherwise, this should look a lot like the voltage case before. Okay. What devices are used to measure current? It depends a little bit on what you're trying to do. For instance, if you're trying to measure all the way down to DC, that does limit you quite a bit to a current probe or some sort of specialty current transducer or current sensor. For instance, the current probes look like the one shown here in the upper right. They are very expensive. Current probes have very wide bandwidth, and they reach to DC. That range of capabilities is expensive, but it can work for a lot of different requirements. It's the all-in-one capability. If you can forgive a little bandwidth and you still want to reach DC, then you can use a specialty current transducer like this one here shown at Danosense. Other companies make these too. Generally, companies that make power analyzers market or make their own version of these. They tend to be much more accurate. They could be a tenth of a percent accurate compared to a current probe, which is maybe 1% accurate, but you do pay a penalty in the bandwidth. This particular one shown here is about a 100 kHz. You can get them up into low MHz or frequencies consistent with what power analyzers are able to measure. Why DC? You just want to be able to understand low frequencies, maybe present at a start-up event, especially if you're looking at a drive output, but DC is probably less critical if you're only looking at sinusoidal AC. What are some other things you can use? Well, your price goes down, and your set of things to choose from goes up if you don't need to measure DC. In that case, you might use something like a Rogowski coil, which is shown there in the bottom right. It's a loop. This is a pretty big loop. They make them small. They make them big. They make them reach closer to DC or they make them go higher in frequency. Typically, the closest you're going to get to DC is about 5 Hz or so for a Rogowski coil. But they do have a very low cost. It's what I call a split-core, which means I can take that loop apart and wrap it around some cables. It's common for people that just want to measure, let's say, the total current in a three-phase system, they can do that by taking the three cables and just putting a big Rogowski coil around it and seeing what they get. Rogowski coil solutions generally have a voltage output after some signal conditioning box, which is shown here attached to the loop, and then that can be easily rescaled in scope. You might have also heard of a Pearson CT. It's the same kind of thing. This is a core coil device, but it has a drop resistor across the output. The output is a voltage, not a current, which is helpful if you're trying to send current signals into something like a scope, which accepts voltage inputs. They make them in lots of different sizes and frequency ranges. Typically, they have a specialized core material, so they're very low flux in the core. In some cases, they might be zero flux, but those get very expensive. You might also use a conventional turns ratio CT, which I don't show here, but that is like what we showed before for the potential transformer. It's just purely like 50 amps in equals 5 amps out. The turns ratio is ten to one. They don't go to DC. You have to install your own shunt resistor, and you've got to do a little bit of work there. They can be very good depending on your application. There's nothing wrong with them, but you do have a little more work to do. We've actually made a sensor adapter, a current sensor adapter. We find a lot of people like the things they have. I will be quite blunt in that current probes like these shown here, expensive, very nice, but not everybody can afford the $2,000 to $5,000 for these kinds of probes per probe, especially multiplied by three for three phases. Some of these things here, the Rogowski coils, the Pearson CTs, are very inexpensive in comparison. They work fine for many people. Many people already have these devices, and all they want to do is make it a permanent connection. So we make this thing called the current sensor adapter. All this does is take the voltage output from your current sensing device. You can program it to be scaled and displayed in amps. You can have it turn a filter on in the software on the scope so it can filter the bandwidth if you don't need 500 MHz of bandwidth, which you're probably not getting out of these devices. It's a very simple device to simplify the setup. It's like what one engineer once described to me: I want something I can program once and just connect a bunch of times and not have to reprogram my scope every time. That could be pretty helpful for those who might not understand everything involved in doing that or when you just want the assurance that if you do it once, it'll be done right from then on forward. Alright. So with that, we'll take another break here really quickly. We have another polling question, and this is about what do you use to measure current? A scope current probe, some sort of specialty current transducer, like I showed before, Rogowski coil, a straight turns ratio CT, or maybe a turns ratio CT with a voltage output like the Pearson CT. So just take a look, and we'll give this about 30 seconds to run its course and report back in. Okay. We still got a few more answers coming in. We'll let that poll run just a little bit longer, and then we'll display the results once we're done. It's always very interesting to see what people do. Here we go. It looks like many people, not surprisingly, use current probes. Fewer people use a specialty transducer, not very many. I find those are very common in electric vehicle, hybrid electric vehicle testing. Looks like Rogowski coils, fairly popular. Some, not insignificant percentage use those, 15% or so maybe. The Pearson CTs, that's a pretty good number. That's roughly 25% or 30%. It's hard for me to see the exact number there. A conventional turns ratio CT, even there, a pretty high percentage of people. Which is very understandable considering this is the line voltage of line AC topic. Thanks for your poll there, and that's very interesting to always see those answers. Alright. Let's talk about power calculations. There are lots of ways to do this. When you start to make power measurements on distorted waveforms, you do need to be very aware of what method it is you're using. I'll explain why that is. If it's pure sine waves, you're going to have a lot easier time for not a lot of money buying something that can measure very well. For PWM outputs, you have to ask a few questions and understand how the measurements are being made. Let's just cover very quickly. I think when I was in college, I learned what I'd call a textbook example of how to measure power. It was always based on sinusoidal AC line voltage and current signals. When I was in college, the textbooks were probably from the fifties and sixties. There weren't too many pulse-width-modulated drives, if any, in those days. A lot of this was pretty out of date by the time I graduated. I'm sure it's taught a little bit differently now, but be aware, if you're using what I call an old-style textbook method, they probably describe the power calculation as being done with knowledge of a phase angle between the voltage and current sinusoids. That's a pretty good method if the distortion is less than 5%, which you can pretty much assume because that's what the utilities have to deliver. Once you get into power conversion, PWM signals, they're very different. They're not sinusoidal. You have to use a different calculation method, which we'll describe. The good news is that different calculation method doesn't have to cost you a lot of money. Specifically speaking, tens of thousands of dollars, I think even fairly good quality handheld portable devices that don't cost a huge amount of money, use this method. That method works for AC line signals as well. When you get into three-phase systems, there are some other complexities in measuring power, specifically around line-to-line voltage probing, which is quite common, the fact that you might have a delta winding, and you also have an opportunity to use a two-wattmeter method calculation instead of using three watt meters, which sounds counterintuitive, but we'll circle back as to why that's a perfectly acceptable method. Okay. First, let's just assume for a moment we have sinusoidal signals, and we're going to do it what I call the textbook classic way where we have two sinusoidal signals, maybe it's supplying a linear resistive load, and it's easy to measure the phase angle between the two signals. Okay. What does that look like in terms of our two vector sets? We have a voltage and a current vector. If it's a linear load, meaning a resistive load, then I have no phase angle between V and I. They're perfectly lined up in phase. That's pretty easy. All I have to do is power equals V times I. I can calculate the instantaneous power at any given point in time because the current vector and the voltage vector are always in phase. However, if I don't have a purely resistive load, if I have an inductive or a capacitive load as they show at the bottom there, then I have this concept called power factor. For an inductive load, the current lags the voltage, or for a capacitive load, the current leads the voltage. The power factor is usually described in angular form as lambda, or the cosine of the angle is the power factor. In that case, in unitless form, it's described as a value from zero to one, not -1 to 0 to 1, but 0 to 1. The one is described or whatever the number greater than zero is described as leading or lagging power factor or inductive or capacitive. If you have a power factor of one, you can derive that. The cosine of zero is one. A power factor of one means you have a purely resistive load. If you have a cosine of a 90-degree angle, then you get zero, and you have a purely inductive or capacitive load. Usually, it's something in between like you're shown here in these two vector diagrams, slightly leading or slightly lagging. If you have sinusoidal waveforms, let's say the voltage and current I show here, you just have a phase difference between the two of them, and the phase difference between the two things at the zero-crossing point is simply the angle. You take time and convert it back into phase, and then you get a phase angle, and that is simply what your phase angle is. You can measure it directly. You can observe it directly. But, in that case, we can use a simple formula. We can't just say power equals V times I in these cases because the two things aren't in phase. We have to use something a little smarter, and we have to know what the power quantities are we're dealing with. In that case, we don't just have what we call real power anymore. We have reactive power, which is the out-of-phase or the quadrature power, which is why it's called Q. Then we have the apparent power, which is S. Why they chose S? I have no idea. But S, it is. S represents the apparent power, which is the quadrature sum of the real and the reactive power as shown here. How do we calculate power in this case? It's pretty simple. When you have a power factor or a phase angle, the nicest way to do this, if you have two pure sinusoidal signals, you can calculate the apparent power by just multiplying the RMS voltage times the RMS current for a given power cycle. That assumes you can measure the true RMS values for that sinusoid, but let's assume you can do that for a minute. If you know the phase angle, then you can calculate the real power by measuring the apparent power and multiplying it by the cosine of the phase angle. That assumes, again, that you can measure phase angle, and that assumes that you have sinusoidal signals. The reactive power can be simply calculated, as you would guess, by doing a quadrature subtraction of the real power from the apparent power, and you can get that. You can get all three of these quantities pretty simply. You might ask at this point, what does the reactive power do for us? Why do we care? The reactive power is really power. It's not doing any work, but it's required for the circuit to operate correctly. If you fail to supply it, then you won't have the apparent power you need to run the actual loads. The reactive power doesn't do any work, but it transfers around in the circuit and is moving around in the circuit, you would say, and it's an essential component of being able to supply the apparent power that the load needs in order to operate. What does this look like in the real world? I took one of our 12-bit oscilloscopes. In this case, this was an 8-channel scope. You can see right here, this is a toaster load. It's a linear load. It's a resistive toaster coil. I'm sure if I had enough accuracy I'd find that it had some slight inductance to it but we can, for our purposes, consider it purely resistive. You can see there's a voltage which is represented with the yellow trace and a current which is represented with the orange trace and it's drawn about 6 A RMS at 120 V RMS. We're obviously seeing peak values here, but I can derive rough RMS values of those. You can see that the voltage and the current signal are pretty much in phase. I can't visually see any difference there. If I were to use some of the tools we have available in our products and I say, look, tell me if I were to say this is a one-phase, two-wire system, voltage C1, current C8, then I can get a table of values and it says, yep, your RMS voltage is about 113.6 V. The current 6.7 A RMS. This is the power, the real power, the apparent power, the reactive power, the power factor. We're with 700-some watts or VA and only 2 VAR (volt-amps reactive) ? what you're seeing is round-off error in the scope and scope's ability to be accurate enough to measure all this stuff. This is a 12-bit scope. It's pretty good, but it has some small error in it, and that's why you're seeing a Q of essentially zero but not quite. Regardless, the power factor, up to three significant digits is 1.000 with a very, very small phase angle that what I would call is within the error of the measurement system. You can see here also, this is a utility-supplied waveform. Yeah. There's a little bit of distortion on there. Why? I have no idea, but you see it in the same place on both the voltage and the current. That actually might be driving a little bit of this reactive power calculation for all I know. Okay. A quick summary. If you have purely sinusoidal signals, you can use what I call the textbook method of measuring AC line power. It works fine. However, most AC line signals have some distortion and or they may have a lot of distortion like a drive output or PWM signal, and that will either impact the measurement accuracy slightly or result in a completely erroneous reading. Let's now talk about how we would measure power on distorted waveforms. Distorted waveforms are everywhere nowadays. I'll show you a couple of examples. If we go way back to our engineering college days, let's say we know that anything that looks like a square wave is a summation of many different sine waves of different frequencies and magnitudes. Here, I've just shown a seventh harmonic, and I've just shown what a square wave would look like if it's built from a variety of sine waves at different frequencies. Yeah, you see here it looks like this. You've got a pretty big fundamental and a bunch of third, fifth, and seventh harmonics that are lower in magnitude. If you add them all up, you get something that's pretty much looking like a square wave, which pretty much is what a PWM output is. As we know, the more harmonics I add in, the more that looks like a perfect square wave. It's really just a bunch of sine waves added together. That's the challenge. If I have a square wave and that's a bunch of different magnitude and frequency sine waves, well, I would have to know the phase angle between all the component sine waves for both voltage and current for that square wave. That's pretty impossible to do. It's not a practical thing to do, and therefore we need a different method. Let's take a look at what the distorted waveform looks like. Well, it looks like this. This is what I call a sinusoidal drive output. It's sinusoidal because it gives a nice sinusoidal current waveform output. You see that classic PWM shape. These are line-to-line voltage signals, but you'll see that if I zoom in this white area right here, and I show that on the inset, I can see, yeah, I've got my very narrow pulse widths here for the output, and this is line-to-line measured, so they're going zero to high, and then there's a pause and it goes zero to low at that crossover point. Even just look at the current, you can see this isn't, it looks like a distorted, fuzzy, noisy pure sine wave, but in reality, when you get close enough into it, you can see a little bit of current increase when the pulse width toggles on, and then it drops when the pulse width toggles off and then ramps up again and so forth. Basically, you don't have a distortion-free sine wave. Even your nice-looking current waveform has quite a bit of distortion on it. That was the best case. Here's a worst case. You can see that this was a heavy load that was causing a drive to overload, but without failing, it was right at the point of overload and you can see here on the currents. Now instead of having what would appear to be a decent sine wave, I've got something that you can see is clearly pretty heavily distorted and I can also see a bunch of misfiring in my PWM signals just above that on the right. If I measure the THD, I'm now well over 5% for voltage and over 5% in some cases for current. Throw everything out the window when you have something that's like a brushless DC motor or commonly called six-step commutated. Those are just horrible, ugly, ugly waveforms. The green, white, and purple waveforms, that's the current, if you didn't know. This whole system works by applying a voltage to only two of the three phases at any given point in time. Why? Well, it's very inexpensive to implement. The control structure is very simple, but it does result in very distorted waveforms, and that's a bit of a problem if you're trying to measure with some very inexpensive conventional power calculation tool. So what do we do? We use a digital sampling system, like an analog-to-digital converter, which are in every modern oscilloscope that I know of, every modern power analyzer that I know of, and probably the better of the handheld type, Fluke meters or things like that, what I call a handheld field technician Fluke or other kind of meter, or power quality analyzer or anything like that. What I'm talking about here is not specific to just things we do. It's a generic method that if somebody's got a digital sampling tool that measures power, they're using this kind of method. Basically what that means is take our signal, which I've shown as a sine wave here, there's a bunch of samples that I've shown as the dots, and we have to take all those samples and put them in groups. The first thing that has to be done is we need to create a calculation period. Here we've got lots of periods. We can see there's more than one period here. Logically, all these samples have to go into defined bucketized periods in order to do our calculation. Step one, help the system understand what the period is. We do that by defining a signal that can function as a zero-cross determiner. Usually, whether it's a power analyzer or scope or something else, the user says, hey, use that input to help me understand what my period is. Usually that input is filtered, and when it's filtered, you get rid of all the distortion on the signal. You get something that looks like a sine wave, like I've shown here in the bottom image. From that sine wave, it's pretty easy. It may seem hard to imagine, but it's pretty easy to calculate the zero crossing with very, very, very high accuracy. The same technique we use for serial data, jitter analysis, when speeds are in the gigabits per second. This is really a walk in the park for drive output waveforms and the speeds that they work at. You have to apply a filter, you get it to look like a sine wave, maybe you have a hysteresis band value to set to, maybe you display what the filtered signal looks like, and in this case, the overlay just helps me understand that I am looking at one period at a time. It gives me the reassurance that I'm doing this correctly. This is the real-world filtered and period-determined result in the bottom left, and this is on the right here is a representation of what we're doing. I only show the one signal in the real, but in the calculations, that one period is applied equally across all the waveforms, and we just say, yep, these are the period locations in time. Now let's make our calculations based on that set. If we go back and we look at that original sine wave with the dots, what this slide says with a lot of text basically is, hey, look at all the points in period one and then in period two and period three and period through period n and bucket all the points, number them and name them and say, look, period one has point 7 through 24. Period two has points 25 through whatever and so on. Once I've got all these points bucketed, then it's really pretty simple to just do some simple things. I can now apply calculation power using my digital sample points. For RMS voltage, I can simply say, for any given period, period one, for instance, what this formula says is take the individual digital values ? that's V J squared ?, take that entire set of point 7 through 24, let's say, and do the square root and then the sum of the squares and then take the average of that and then do the square root of that, and you get the RMS value for that period. And the same thing for current. Remember early on, I said, to understand what the apparent power is, we want to measure RMS voltage and RMS current and multiply those two things together, and we get apparent power. We do the same thing here. The only difference in this new calculation method is to measure the real power we don't need to know anything about the phase angle. To measure the real power, it's just the instantaneous power. For every point, let's say point seven for voltage and point seven for current, we just multiply those two different digital point values together and we add them all up and take the average, and that is our instantaneous power value for the cycle. Once we have the real power or instantaneous power and the apparent power, again, simple method to simply calculate the reactive power by doing the quadrature subtraction of the real power from the apparent power, just like before. This gives us per-cycle values in this middle column. On the far right, I just show then you normally take the average value of that in a static situation and you display that in the table. That's the number that pops up on your power analyzer or the number that could appear in our table and our calculation. It's the mean average number under a steady state load. How do we get power factor and phase angle? Pretty easy. I just take the apparent power and divide that into the real power. That's my power factor. I can do the same thing for the magnitude of the phase. It's simply equal to the inverse cosine of the phase angle. This is the most generic way to think about it for a single-phase set with line-to-neutral, voltage waveforms, and line currents. It gets a little more complicated as we'll describe all the details here. If you are curious about how this is all done for a variety of single and three-phase systems, you can reference that link, and that'll give you pages and pages and pages of calculations. Power analyzers usually have similar tables that are informative as well. Okay. So conclusions. If you're looking at distorted waveforms, which are very common, you can't use the simple, most basic calculation method. You have to use this better one. The good news is the digital sampling technique, the better technique, also works for pure sinusoids. Last polling question. Tell me what kind of signals you measure power on. If you measure power, sinusoidal only, PWM or distorted signals only, or some combination of the two? We'll just give you a few seconds here to answer this question. Okay. A few more answers still coming in. We'll just give that a little bit more time, and then we're going to wrap up pretty quickly. We're just about at the end here. Probably running just a little bit over. I've got to cover the three-phase section here too real quick. Okay. We'll just show this real quick, and most of you are doing a combination of both. Not surprising. That's kind of the definition of power. If you have a three-phase system and it's a resistive load, it's just three times the case we described earlier. If you've got a line-to-line signal, you first have to convert it to a line-to-neutral basis, but otherwise, it's the same thing. The line-to-neutral conversion is pretty simple. If it's a non-resistive load, meaning the phase angle is not zero, then you just have to do a conversion, probably to a line-to-neutral basis if you haven't already done that for voltage, and then you just have to use that more complex method to calculate the powers. Where it can get a little weird is if you have a well, let me just back up a second. If you have a line-to-neutral system and you're measuring voltage line-to-neutral, that's easy. You've got both a voltage and a current that are in phase with each other. The calculations are very straightforward. Even if you have a different phase angle, again, very straightforward. This is just a three-phase case for what we described earlier in the single-phase case, and you just do each phase one at a time, add them all up, and you get your total power, you get your total apparent power, real power, and the reactive power. But there are some exceptions. If you have to measure voltage line-to-line, your voltage value will be out of phase and magnitude with the current. If you have a delta winding, you have a terminal current versus a coil current. You just need to know that. You can also use the two-wattmeter method. You don't have to measure all three phases. You can do something called the two-wattmeter method, which we'll describe in a minute. The three-phase line-to-line, we showed this earlier. This is out of phase by 30 degrees and often magnitude by the square root of three, so you just have to do a conversion. To measure the power, you take your line-to-line, you do a magnitude and phase transformation, you get a line-to-neutral basis voltage, and then you do the calculations very simply as you did before. Remember, a wye is different than a delta. A delta never has a neutral winding. Most times people are probing line-to-line, and the currents are line currents. Even if you do the conversion in the delta case, remember that the line current is not the coil current. It's the current that's flowing into this terminal, B in this case, the top, and it's the current's dividing between these two. The currents flowing from the opposite terminal are also subtracting or adding into that coil. It's pretty complex. You're dealing with a coil current in that case. You just have to know that. I'm sorry. We can't see the slides. You're right. I don't see it anymore. Okay. Hold on. I'm sorry about that. Let me just make sure I haven't lost the wireless connection. Looks like I'm good. Okay. I'm just going to disconnect my wireless for a minute, reconnect, and I might have to sign back in. Okay. There we go. It looks like it reappeared for me. I'm still connected. Hilary, are you still able to see it? Okay. Great. Okay. I'm just going to run back. I guess we're going to run a little bit over. I'm just going to pause on each one of the slides I presented earlier so you can connect my comments with the slide. It's a little clumsy, but we'll have to make this work today. I'm showing the three-phase calcs if you have a line-to-neutral system. Straightforward calcs, you just calculate each thing independently, you add up all three phases, you calculate the real, apparent, and reactive power as before. With the single-phase case, you just add up the three phases together, but the exceptions are you might be line-to-line, not line-to-neutral for voltage, you might have a delta winding, or you might be using a two-wattmeter method. If it's line-to-line voltage, you have to do a conversion in both magnitude and phase, as I described, that's relatively straightforward mathematically, and once you do that, then you can just do your calculations and all the formulas work, by adding the three-phase calculations for the converted line-to-neutral voltage and line currents together. If you have a delta winding, you just have to know you're going to be probing line-to-line. The current is the terminal current going into B in this case, so it's not something that represents the coil current. That's different, so it's just something to know. Typically, again, if you're a delta, now you're line-to-line voltage, you have to do the conversion itself and measure the current, measure the voltage and the currents, and then calculate the total three-phase power as described earlier. Now where we left off, in speaking is on this two-wattmeter method case. Here, you can actually, instead of using six signals to calculate three-phase power, which you might think you have to have, you can use two voltage signals and two current signals. You can probe them this way, and you can make the assumption that at the neutral point, the currents and the voltages add up to zero. When you do that, you can get two out of the three and solve for the third. Mathematically, that's what this says. If you want to read the theorem yourself, just look it up two-wattmeter theorem or Blondel's theorem will give you the information you need to convince yourself this is okay, but it does work. It works for both a wye system or a delta system. It's widely used and mathematically valid for a balanced three-phase system, and almost all three-phase systems, unless something's going horribly wrong, are balanced. Guess I should be making that slide bigger. Okay. Just a real quick look at what these things look like. This is just a capture on one of our 8-channel motor drive analyzers. At the very top, this is zooms of the line-to-line voltages. These are the currents. You might assume the AC input currents are going to be nice sinusoids, but they're not. Remember, it's a nonlinear load. It draws currents in a very pulsy way, which is why these look pulsy and not sinusoidal at all. The output of the drive is this blocky looking PWM shape alternating high and low. The current, it's pretty noisy, pretty distorted. If you were to filter that out, you'd see something that looked like a sine wave. This is a very long acquisition, and what I just show on the right are some calculated power values that or efficiencies, that change over time as the load is increased. We're running a little short on time, so I won't go any further there. If any of you use a power analyzer, there's one thing I get this question a lot. Most power analyzers are set up to be naturally connected in a two-wattmeter method, and they do all their calculations on a two-wattmeter method basis. Therefore, they require a different input connection setup than our products do. You'll still get the right three-phase answer. It's not like you're measuring three-phase power wrong, but if you look at all the signals at one time, you might see some weird phase relationships. The per-phase values for the A and C phase might be a little weird, because they're using a two-wattmeter method. The voltages and the currents, which are shown in this vector diagram on the right, are not aligned in phase or not corrected in phase to give correct per-phase values. The total three-phase value will be correct. Okay. Just a quick conclusion for three-phase. If you're measuring line-to-neutral, calculations are pretty straightforward. Simple extension to single-phase. If you're measuring voltage line-to-line, you have to convert voltage in phase. In magnitude, it's pretty simple to do. We do it automatically as do other instruments as well. The conversion is once it's performed, the calculations are a simple extension of the single-phase case. You can use a two-wattmeter method. It's a proven method. It's accurate. It's widely used. It's okay. The one disadvantage, if you're a design engineer, you usually like to see visually all the signals. Once you've done your debug and you just need a number, it's pretty okay to go to a two-wattmeter method. During debug, you probably want to see all three voltages and all three currents. Quick closing comments. We have a website you can go to. It's got a lot of information on it. You can request these two posters. We have a technical primer that might be helpful to you. There's some good information there. There's also some app notes on how we apply power calculations in our products. We just did a webinar a few weeks back. It's on demand. It's measuring motor performance using power analyzers and oscilloscopes. We'll be scheduling part two, which gets to power conversion, from devices to complex drives. That'll be scheduled probably sometime in the next month, and we'll let you know when that's scheduled so you can sign up for that. Otherwise, we'll just take any questions that you have at this time. I'm just going to pause for a moment and rest my voice while I look over the list. Okay. The first question is, how are the different source phases synced? It's a great question. The question is are they synced with a PLL or something else? If it's a power analyzer, they normally use a hardware PLL to understand how to set that period. We're using what's essentially just a software algorithm. In most cases, they'll both work fine with the power analyzer. With the hardware PLL, there might be a delay, or they might not be able to respond as well with very fast-changing dynamic events. In a static case, where you're measuring steady state power, both methods would be fine. In a dynamic case, you might find a hardware PLL method might fall a little short, really depends. The advantage of a hardware method is you don't require an algorithm that requires a little bit of processing time. The next question is residential performance. There's a voltage-to-current phase concern of products to correct. I think I understand the question to be, if you have a 120 V line coming in your house, do you normally have a phase angle between the voltage and current? You really shouldn't. It should be pretty close to being power factor one. It's possible to have just so many crazy inductive loads or whatever in your house that it might impact it a little bit. It's probably very, very close to power factor one, and the wattmeter that measures your power in any case is going to not charge you by the apparent power, it'll charge you by the real power. The next question is, since you need a current chain, dI/dT, to measure current going through a loop coil, how do you measure a DC current? The devices that measure DC are all using Hall effect sensors, so current probes. They contain a Hall effect device, and they also contain a coil, and there's some crossover in the kHz range, maybe a 100 kHz where the coil and the core technology takes over from the DC Hall effect technology. I won't be able to tell you how the Hall effect technology works to measure DC, but that is the device that you use to get down to DC in that case. These are great questions. The next question is why Rogowski coils are rated in mV instead of milliamps even though they're used in smart meters for measuring currents. A great question. I don't really know except that I think they're a voltage measurement device, I think, that uses some power conditioning to understand how to turn that voltage signal, which is a nonlinear voltage signal, into a linear current reading. That would be a great question to ask the folks at, like, PEM UK or something like that. If you're at APEC in two weeks, that's a great question for them, and I'm going to try to remember that one myself, and I'll quiz them about it too. The next question, we have three more. What is the best way to measure the current draw directly on a PCB apart from factoring in the voltage drop? I = V/R using a multimeter directly in a path. A lot of times, the first method that you've acknowledged there is use a series or a shunt resistor and then measure a differential voltage across that shunt resistor. Knowing the resistor value and the voltage drop, you can calculate current from that. That's very common. If you can get a loop in the circuit and you can tolerate the presence of the inductance from that loop in the circuit, you can get a current probe around that loop coil and get a reading that way. A lot of people don't find that the best way to do it. Otherwise, those are really the only two practical methods. It's really going to involve some shunt or series resistor voltage drop measurement or just putting something in a circuit to get a current probe into. Next question. AC power from the source such as a generator has out of phase 90-degree between voltage and current, and why does it out of phase between voltage and current? I don't really understand the question. I don't agree that the voltage and current is 90-degree out of phase. In general, it's being generated in phase. By the time it transmits over very long cables, you're going to get some phase shift, and that's generally corrected for by the utility through a variety of, like, capacitive compensation schemes or things like that. But in general, as best I know, a generated power has in-phase voltage and current. Last question is, will there be a link to webinar video? Yes. It'll be sent out. Thanks for your attendance and your kind comments and your great questions. They were really good questions. I appreciated them all. Unless there are further questions that pop up here, I think we're done. I appreciate the time you spent with us today. We'll archive the webinar, and you'll get a link. Thank you very much, and I hope you'll be joining us for part two as well. Thanks again and have a great day.