APPENDIX J


HYDROLOGY AND WATER QUALITY

J-1      Technical Report on Airport Drainage, Northern Sector – Airport and Ordinance Creek
         Watershed / Preliminary Creek Constructed Natural Channel Culvert
J-2      Preliminary Stormwater Mitigation Plan / SUSMP Assessment
J-3      Technical Report on Airport Drainage, Northern Sector – Airport and Ordinance Creek
         Watershed, Airport Creek Hydrologic Models




Charles M. Schulz - Sonoma County Airport
Draft Environmental Impact Report                                                       July 2011
                                                J-1

===== x_appendix_j-1_-_1-8.pdf | PDF page 2 of 11 =====
Appendix J – Hydrology and Water Quality


                                 THIS PAGE INTENTIONALLY LEFT BLANK




Charles M. Schulz - Sonoma County Airport
Draft Environmental Impact Report                                     July 2011
                                                  J-2

===== x_appendix_j-1_-_1-8.pdf | PDF page 3 of 11 =====
APPENDIX J-1
Technical Report on Airport Drainage, Northern Sector – Airport and Ordinance Creek
Watershed / Preliminary Creek Constructed Natural Channel Culvert

===== x_appendix_j-1_-_1-8.pdf | PDF page 4 of 11 =====
                              Technical Report on Airport Drainage

          Appendix J-1: Northern Sector – Airport and Ordinance Creek Watershed

        Preliminary Design – Airport Creek Constructed Natural Channel and Culvert

Introduction

The proposed project includes extension of runway 14-32 to the northwest, which will include the
construction of fill over the existing Airport Creek natural channel (as well as a ditch interconnecting
Airport Creek with Ordinance Creek), with fill extending as far as 1000 feet to the north of the
existing creek channel. The normal design event for Airport Creek in this location is the 25-year
event, based on an upstream tributary area of approximately 2 square miles, which places it in the
category of a secondary waterway. However the proposed improvements (fill for the runway
extension) combined with high existing grade elevations north of the realigned Airport Creek
channel will not allow overland relief of 100-year event runoff, therefore per Sonoma County Flood
Control Design Criteria, the design event for the evaluation of these improvements is the 100-year
storm. The project proposal includes realignment of Airport Creek and the creation of
approximately 700 feet of constructed natural channel leading into a culvert of approximately 650
feet in length under the runway extension fill. The constructed channel and culvert, with a
connection at each end into the existing Airport Creek channel, are proposed to replace the portion
of the existing creek channel that will be covered over by the runway extension project. The portion
of the creek channel to be rerouted also includes a replacement of the interconnection ditch leading
to (west) Ordinance Creek that will need to be reestablished as a part of the final design of the
Airport Creek channel improvements, in order to continue to maintain existing drainage flow
patterns in Ordinance Creek west of the runways. The proposed project includes a second, smaller
culvert to interconnect Airport and Ordinance Creek for this purpose.

Based upon the project description, the replacement channel/culvert will realign and connect
Airport Creek from HEC-RAS River Stations 1.428± to 1.145±, meaning approximately 1,500 feet
of natural channel length will be replaced by a combined 1,350 feet of constructed natural channel
and underground culvert beneath the runway extension fill.

The proposed constructed natural channel configuration is a trapezoidal channel with a bottom
width of 30 feet and 4:1 side slopes. Ultimately, the final design for the channel will also include
provisions for low-flow conditions, however for the purposes of this report the preliminary
calculations provided herein do not include this minor effect on the overall geometry of the channel.
The proposed channel is required to satisfy Sonoma County Water Agency (SCWA) Flood Control
Design Criteria (SCWA, 1983) with a minimum freeboard requirement (vertical distance from the
design water surface to top of bank) of 1.5 feet or 0.2 of the specific energy (v2/2g) of the design
flow, whichever is greater. The required minimum radius of the “reverse curve” configuration of the
channel realignment is three times the top width (width of water surface for the design event) of the
channel.

The proposed constructed natural channel has been assigned a Manning’s “n” value of 0.08, which is
consistent with design values typically applied in the Windsor/Airport locale for natural creek
riparian zones, representing a vegetation matrix that has theoretically been allowed to evolve
naturally and is fully developed. It is also consistent with field observations of the dense understory
                                                                                                   J-1-1

===== x_appendix_j-1_-_1-8.pdf | PDF page 5 of 11 =====
vegetation to be found within the existing natural channel along the local reach of Airport Creek.
We understand there are restrictions as to the height of vegetation that can remain unmaintained
beneath the airspace restrictions of the runway, implying that a certain degree of creek channel
maintenance can be expected over time. However for the purposes of this report, a conservative “n”
value of 0.08 has been applied to the constructed natural channel for the backwater calculations and
to evaluate channel conveyance capacity.

The proposed design for a culvert to convey Airport Creek flow beneath the runway extension fill is
a multi-barrel reinforced box culvert. Headwalls and wing walls will be provided to resolve the grade
discontinuities at the culvert entrances. Debris walls – downward-slope angled walls projecting from
intermediate culvert support walls - will be included at the culvert inlet to minimize obstruction of
the culvert entrance. Local turbulence which may cause scour at the culvert outfall would be
prevented by providing suitable channel stabilization materials at the outfall. This may be in the
form of an apron of graded rock rip-rap as well as a prism of channel soils stabilized by one or more
alternative materials and methods now available to the designer, or even in combination, to result in
an acceptable installation that will minimize local channel erosion. In accordance with the
requirements of the Sonoma County Water Agency (“SCWA”), this culvert is required to be
adequately sized not only to convey the 100-year event but must also do so with at least one foot of
freeboard between the water surface and the soffit of the culvert. In addition the design must
consider debris obstruction at the entrance. The SCWA standard is to assume 1 foot either side of
the intermediate box culvert support walls. (Note: Use of 2:1 sloped debris walls extending out from
the intermediate box culvert support walls at the culvert entrance allows for limiting the zone of
potential debris blockage to the upper two feet of the culvert opening.)

The ability of the culvert to structurally support potential loading must also be considered as a part
of the culvert design. The proposed culvert alignment does not run beneath the actual paved
runway, but beneath fill in the safety zone at the end of the runway. It is conceivable that at some
point in the future the culvert may be subject to airport runway live loads in addition to the dead
load of the fill, and because replacing such a facility is potentially very difficult and costly, it would
be prudent to assume such loading in the subsequent engineered structural design of the culvert
elements.

Preliminary Hydraulic Calculations – Reinforced Box Culvert

Design Storm Event = 100-year flow: Q100 = 955.5 cfs (318.5 cfs/barrel)

Downstream Channel Depth of Flow = 9.6 feet

Allowable Downstream Tailwater Depth = 7 feet (assuming an 8 foot culvert height dimension)

Downstream Channel Flowline Elevation = +81.0*

Downstream Culvert Invert Elevation = +83.6*

Culvert Invert Slope s = 0.15% (0.0015 ft/ft)

Upstream Culvert Invert Elevation = +84.6*
(*all elevations shown based on NGVD 1929 vertical datum)

                                                                                                       J-1-2

===== x_appendix_j-1_-_1-8.pdf | PDF page 6 of 11 [OCR] =====
BOX CULVERT ANALYSIS
COMPUTATION OF CULVERT PERFORMANCE CURVE

May 13, 2011

 

PROGRAM INPUT DATA

        

 

   

     

DESCRIPTION VALUE
Culvert Span (ft). Deere eee eee 10.0
Culvert Rise (ft). vase enees tee . 8.0
FHWA Chart Number....... . . wee eens . . 8
FHWA Scale Number (Type of Culvert Entrance) beeen eeneee 1
Manning's Roughness Coefficient (n-value) beeen eens 0.012
Entrance Loss Coefficient of Culvert Opening........ . 0.5
Culvert Length (ft). .cccveee cece eee ee eee rare 650.0
Invert Elevation at Downstream end of Culvert (ft).. . 83.6
Invert Elevation at Upstream end of Culvert (ft).. . 84.6
Culvert Slope (£t/Et). cece sec e eee eee e eee e eer ee ene . 0.0015
Starting Flow Rate (CfS)....eeeeeeee ween eens 318.5
Incremental Flow Rate (cfs).....-.0- . sane 0.0
318.5

 

Ending Flow Rate (cfs)....

 

Starting Tailwater Depth (Et)... eee eee eee eee eee eee eens

7
Incremental Tailwater Depth (ft) ...ecesee eevee eee eee eee eee oe QO.
Ending Tailwater Depth (ft)... ccc e eee e cece eee eee ee eee eee 7

 

COMPUTATION RESULTS

Flow Tailwater Headwater (ft) Normal Critical Depth at Outlet
Rate Depth Inlet Outlet Depth Depth Outlet Velocity
(cfs) (ft) Control Control (ft) (ft) (£t) (fps)

 

HYDROCALC Hydraulics for Windows, Version 1.2a Copyright (c) 1996

Dodson & Associates, Inc., 5629 FM 1960 West, Suite 314, Houston, TX 77069
Phone: (281) 440-3787, Fax: (281) 440-4742, Email:software@dodson-hydro.com
All Rights Reserved.

===== x_appendix_j-1_-_1-8.pdf | PDF page 7 of 11 =====
Preliminary Hydraulic Calculations – Ordinance Creek Crossover Flow Conduit

The HEC-RAS model of the existing conditions in Airport Creek includes a crossover ditch that
transfers a part of the flow in Airport Creek to (west) Ordinance Creek when Airport Creek is
flowing at a sufficient depth to spill over into the crossover ditch. This ditch will be filled as a part
of the proposed project. In order to preserve this flow contribution to the upstream reach of (west)
Ordinance Creek a second, smaller culvert approximately 600 feet in length is proposed beneath the
runway extension fill that is to be designed to provide an equivalent amount of flow transfer.
Preliminary sizing of this crossover culvert assuming 100-year conditions results indicates that a
single 8’ wide x 4’ high reinforced box culvert will provide the needed flow capacity and backwater
profile to induce the crossover flow to leave the main Airport Creek channel and flow into
Ordinance Creek. The amount of flow transferred by the existing crossover ditch is shown in the
HEC-RAS model for the following distinct storm events:

Storm Event                    Crossover Flow

2-year                          57.4 cfs

10-year                         83.2 cfs

25-year                        107.1 cfs

100-year                       115.0 cfs

The previous calculations for the primary box culvert assumes that capacity of the crossover culvert
will accommodate the 100-year flow of 115 cfs and that it will be constructed at an elevation that
will hydraulically allow 115 cfs to separate out of the main creek flow, i.e. the upstream energy grade
line (EGL = HGL + v2/2g) the crossover culvert is no higher than that of the main culvert at the
point where the crossover culvert connects into Airport Creek.

Design Storm Event = 100-year flow: Q100 = 115 cfs

Downstream Channel Depth of Flow = 9.6 feet

Downstream Tailwater Depth = 4.74 feet (W.S. Elevation = +91.74* @ “Crossover” R.S. 0.0286)

Downstream Channel Flowline Elevation = +87.0 (Note: existing crossover ditch will require
lowering by approximately two feet from the connection to Ordinance Creek to the crossover
culvert outlet)

Proposed Downstream Culvert Invert Elevation = +87.0*

Culvert Invert Slope s = 0.17% (0.0017 ft/ft)

Proposed Crossover Culvert Length = 600 feet

Upstream Culvert Invert Elevation = +88.0*
(*all elevations shown based on NGVD 1929 vertical datum)

                                                                                                    J-1-4

===== x_appendix_j-1_-_1-8.pdf | PDF page 8 of 11 [OCR] =====
BOX CULVERT ANALYSIS
COMPUTATION OF CULVERT PERFORMANCE CURVE

May 13, 2011

 

PROGRAM INPUT DATA

 
 
 
     
  
   
   
  

   

 
 
 

 
 
 
 

Culvert Span (ft). 8.0
Culvert Rise (ft). 4.0
FHWA Chart Number... . 8
FHWA Scale Number (Type of Culvert Entrance) 1
Manning's Roughness Coefficient (n-value).. 0.012
Entrance Loss Coefficient of Culvert Opening 0.5
Culvert Length (£C) sc. ccc c cece eee ee ee eee eee e nee 600.0
Invert Elevation at Downstream end of Culvert (ft) 87.0
Invert Elevation at Upstream end of Culvert (ft).. 88.0
Culvert Slope (ft/ft) 0.0017
Starting Flow Rate (cfs)..... 115.0
Incremental Flow Rate (cfs), 0.0
Ending Flow Rate (cfs) 115.0
Starting Tailwater Depth (ft) 3.9
Incremental Tailwater Depth (ft). 0.0
Ending Tailwater Depth (ft) 3.9

 

COMPUTATION RESULTS

Flow Tailwater Headwater (ft) Normal Critical Depth at Outlet
Rate Depth Inlet Outlet Depth Depth Outlet Velocity

(cfs) (ft) Control Control (ft) (ft) (ft) (fps)

  

115.0 3.9 2.97 3.58 2,24 1.86 3.9 3.69

 

HYDROCALC Hydraulics for Windows, Version 1.2a Copyright (c) 1996

Dodson & Associates, Inc., 5629 FM 1960 West, Suite 314, Houston, TX 77069
Phone: (281) 440-3787, Fax: (281) 440-4742, Email: software@dodson-hydro.com
All Rights Reserved.

===== x_appendix_j-1_-_1-8.pdf | PDF page 9 of 11 =====
Preliminary Hydraulic Calculations - Constructed Natural Channel

The constructed natural channel connecting the culvert inlet back into the natural channel of Airport
Creek will be constructed through elevated ground north of the existing natural channel. The design
alignment is a reverse curve to route flow first to the north out of the existing channel alignment,
then turning east to flow directly into the culvert entrance. Hydraulic analysis of the proposed
channel dimensions indicate that the maximum depth of flow in the constructed channel will be less
than 8 feet. If one assumes this depth of flow in the proposed trapezoidal channel cross section
geometry with 4:1 side slopes and a 30’ wide channel bottom, the top width of flow would be 2 x (8’
x 4) + 30’ = 92 feet. Therefore, the proposed minimum centerline radius of the curved portions of
the constructed natural channel shall be equal to or greater than 3 x 92’ or 276 feet.

From the results of the calculations for the culvert, the downstream tailwater depth of flow for the
constructed channel during a peak 100-year event is approximately 7 feet. At the upstream end of
the constructed natural channel, assuming a Manning’s “n” value of 0.08, the water surface profile
calculations show that the 100-year hydraulic grade line (HGL) of +93.1 will be lower than
calculated for the existing channel (+94.6) at the location where the constructed natural channel
rejoins the existing channel of Airport Creek at River Station 1.428. This would be expected as the
replacement culvert/constructed natural channel has higher nominal conveyance capacity exhibits
lower hydraulic losses from friction, and is also about 150 feet shorter in physical length than the
existing (slightly meandering) natural channel that is proposed to be replaced as a result of the
project. Flow velocity in the constructed channel is less than 3 ft/second for the 100-year flow.
Water surface elevations will range from +91.6 to +93.1, requiring a minimum elevation of the
constructed channel top of bank to range from +93.1 to +94.6 to provide at least 1.5 feet of
freeboard.




                                                                                                 J-1-6

===== x_appendix_j-1_-_1-8.pdf | PDF page 10 of 11 [OCR] =====
TRAPEZOIDAL CHANNEL ANALYSIS
STANDARD STEP WATER SURFACE PROFILE COMPUTATION

May 13, 2011

 

PROGRAM INPUT DATA

 
      
 
 

 

  
 
  

Flow Rate (cfs). 1,070.7
Channel Bottom Slope (£t/Et) 0.0013
Manning's Roughness Coefficient (n- value). . 0.08
Channel Left Side Slope (horizontal/vertical).. 4.0
Channel Right Side Slope (horizontal/vertical) 4.0
Channel Bottom Width (ft)... ceesee eee ee cece cece eee tence nee 30.0
Flow-Line Elevation at Starting Station (ft) 84.6
Water Surface Elevation at Starting Station (ft).. 91.6
Starting Channel Station (ft) 0.0
Ending Channel station (ft). 700.0
Channel Length (ft)..... 50.0

   

 

 

Normal Depth (ft).... 8.3
Critical Depth (ft).. 2,97
Channel Flow-Line ws Channel Flow Flow Velocity EGL
Station Elevation Elevation Depth Area Velocity Head Slope
(£t) (£t) (ft) (ft) (sq ft) (fps) (ft) (£t/£t)
0.0 84.6 91.6 7.0 406.0 2.64 0.108 0.002614
50.0 84.66 91.73 7.07 411.71 2.6 0.105 0.002516
100.0 84.73 91.86 7.13 417.02 2.57 0.102 0.002429
150.0 84.79 91,98 7.18 421,98 2.54 0.1 0.002351
200.0 84.86 92.1 7.24 426,62 2.51 0.098 0.002282
250.0 84,92 92.21 7.29 430.98 2.48 0.096 0.002219
300.0 84.99 92.32 7.33 435.07 2.46 0.094 0.002163
350.0 85.05 92.43 7.38 438,93 2.44 0.092 0.002111
400.0 85.12 92,54 7.42 442,57 2.42 0.091 0.002064
450.0 85.18 92.64 7,46 446.0 2.4 0.09 0.002021
500.0 85.25 92.74 7.49 449.26 2.38 0.088 0.001981
550.0 85.31 92.84 7,53 452.35 2.37 0.087 0.001944
600.0 85.38 92,94 7,56 455.27 2,35 0.086 0.00191
650.0 85.44 93.03 7.59 458.05 2.34 0.085 0.001879
700.0 85.51 93.13 71.62 460.7 2.32 0.084 0.001849

 

 

   

EYDROCALC Hydraulics for Windows, Version 1. 2a Copyright (c) 1996

Dodson & Associates, Inc., 5629 FM 1960 West, Suite 314, Houston, TX 77069
Phone: (281) 440-3787, Fax: (281)440-4742, Email: software@dodson-hydro.com
All Rights Reserved.

===== x_appendix_j-1_-_1-8.pdf | PDF page 11 of 11 =====
Summary of Results

The proposed culvert configurations use standard box culvert sizes and will meet the requirements
of the Sonoma County Water Agency Flood Control Criteria based on the parameters described in
the calculations. The proposed configuration of the major culvert conveying Airport Creek under
the runway improvements is a triple box culvert made up of three 10’ wide x 8’ high conduits. The
calculation results show that there is adequate flow capacity and freeboard provided by this
configuration. Outlet velocity is within an acceptable range of less than 5 feet per second for the
100-year event. If it is desired to reserve the first one or two feet culvert bottom for channel bottom
gravel material enhancement, the actual box culvert vertical dimension should be increased
accordingly.

The proposed cross connection culvert is an 8’ wide by 4’ wide box culvert. Because the Ordinance
Creek channel is at higher flowline elevations than the Airport Creek channel, there is a very limited
window of elevation differential that can be used to redirect a portion of the Airport Creek flow into
Ordinance Creek. The existing ditch from the cross connection outfall to Ordinance Creek (a
distance of approximately 150 feet as the outfall is depicted on the maps accompanying the project
description) will need to be excavated down about 2 feet to permit enough hydraulic grade in the
cross connection culvert to do this. The calculations for the configuration provided in this report
show that specifically for the 100-year event, the theoretical cross-connection flow is maintained.

The calculations for the constructed natural channel indicate that the proposed cross section will
adequately convey the 100-year event, provided that finished top of bank is at least 1.5 feet higher
than the calculated 100-year water surface elevation along the length of the new channel. The
channel realignment trends north into an area of higher elevation than adjacent to the existing
Airport Creek channel to be replaced, so this requirement should be easily met by the finish grade,
except for the transition zone at the point where the channel connects into Airport Creek. However,
overbank flow in this area will not impact any existing buildings or facilities in the flood plain, and
would qualify for an exception to freeboard requirements for existing conditions as described in the
SCWA Flood Control Design Criteria manual.

Finally, the hydraulic improvement realized by the construction of the box culvert and realigned
constructed natural channel will result in no increased water surface elevations upstream of the point
where the constructed natural channel connects back into the existing Airport Creek channel. This
also means that Redwood Creek, which has a confluence with Airport Creek a short distance
upstream from the proposed channel realignment, will not be hydraulically impacted by the project.
By the same token the location where Airport Creek crosses the limits of the Sonoma County
Airport parcel, even further upstream, will also not be hydraulically impacted by the project.




                                                                                                  J-1-8